Asterisk 1.6? on Ipitomy IP5000.
I can connected to the AMI just fine. I can issue:
Action: Originate
Channel: sip/122
Exten: 5556666 (i use my own cell number here)
Context: default
Priority: 1
Timeout: 30000
This causes my desk phone to ring, when I answer the system hangs up. The call isn't connected to my cell number.
I have also tried the above with:
Context: from-internal
and
Async: True
All have the same result. I'm also fairly sure that it is Asterisk 1.6 because Action: ListCommands shows commands that weren't available until 1.6
The answer was the Context: I used Action: Status to see what outgoing calls looked like on this system. Noted Priority and Context then tried these inside my PHP script. Bang, it placed the call like i wanted.
I cannot however get it to set a CallerID name even using Callerid: "Test" 5555555555 (this is an example as I'm suing the real numbers)
Related
we bought a Printronix RFID printer T4304 with these dates:
FirmwareP301189 V1.21A
Serial NumberT4K431948007
Our wish is
to produce RFID-Labels with an QR-Code which includes the EPC-number
of the label. The QR-Code shall look like this:
http://qr.mycompany.com/epc/E280689123456789012345
We were hoping to use it with the Software Nicelabel. But Nicelabel
is only able to produce a QR-Code with only the EPC-Number but not
with our http://qr.my..../epc/ in front.
I had the idea to save the printjob as file. So I was able to
manipulate the file and send that file as printjob to the Printronix
printer like this:
lpr -S 192.168.1.2 -P raw myprintjob.prn
I found the document PTX_PRM_PGL_P7_253642C.pdf
which describes how the printer language is working. But I cannot
fulfill my destination.
My myprintjob.prn looks like this:
!PTX_SETUP
ENGINE-IMAGE_SHFT_H;0
ENGINE-IMAGE_SHFT_V;0
ENGINE-WIDTH;04146.
PTX_END
~NORMAL
~PIOFF
~DELETE LOGO;*ALL
~PAPER;INTENSITY 8;MEDIA 1;FEED SHIFT 0;CUT 0;PAUSE 0;TYPE 0;LABELS 2;SPEED IPS 6;SLEW IPS 6
~CREATE;FRM;99
SCALE;DOT;300;300
RFRTAG;96;EPC
96;DF511;H
STOP
ISET;0
FONT;FACE 92250
ALPHA
AF511;24;INV;POINT;329;1033;10;10;
STOP
BARCODE
QRCODE;INV;XD9;T2;E0;I1;95;843;
"http://qr.mycompany.com/epc/","EPCCODE"
STOP
END
~EXECUTE;FRM
~REPEAT;1
~AF511;<DF511>
~NORMAL
The result is a QRcode which only includes the first part of the string:
"http://qr.mycompany.com/epc/"
but not the "EPCCODE". I am looking for a hint how to do this.
Maybe I could find out the EPC-code via REST or telnet or so and create a special printjob for every single label?
Thanks for your help,
Richard
Printronix T4000, talk with port 9100 to get info from the printer
Author
Richard Lippmann, Stadt Zirndorf, EDV
Documentinformation
name: talk-with-port9100-to-get-infos-from-printronix-rfid-printer.md
revision: 2021-12-02 - init
What I want to achieve
I want to know the RFID-code from the label which is under the print-head.
With this information I am able to build a printjob with Qrcode which includes
the RFID-EPC.
I was not able to find out how to create a print-job with a qr-code.
I do not want this information in qrcode: ABC1234...567
But I want this information in qrcode: http://qr.mydomain.com/rfid/epc/ABC1234...567
With that I am able to take a picture of the label and go to a web-application
which helps me further with the device the label is on.
Documenation, where to find information
The printer language is described in the document which is easy to google: PTX_PRM_PGL_P7_253642C.pdf
My environment
Printronix T4000 printer with RFID-unit to read the RFID from the current label.
How to get info back from my printer
Usually Port 9100 is used to send a printjob to the Printronix-printer. Send job,
don't receive data. But you can switch the printer to be verbose, to send you
back information over the 9100-connection.
Glossary
EPC = this is the unique number which is in every RFID-label, just like
a MAC-address in a network card
PGL = the printer language. We can send printjobs with it, but also get information
from the printer about Configuration etc.
Human connect to the printer via Linux commandline
ssh me#shell.mydomain.com
export MYPRINTER=192.168.100.3
nc -v $MYPRINTER 9100
Put verbose mode on
The printer usually only receives information, but does not talk back.
You have to switch on the back-communication.
~CONFIG
SNOOP;STATUS
END
Put verbose mode off
I you are programming this interface with a programming
language like python, perl, ... it's a good idea to switch
verbose mode off after you did your job.
~CONFIG
SNOOP;OFF
END
IDENTITY
To see information:
put verbose mode on
send ~IDENTITY command
put verbose mode off
~CONFIG
SNOOP;STATUS
END
~IDENTITY
The result is:
T43040,V1.21A,12,131072KB
STATUS
To see information:
put verbose mode on
send ~IDENTITY command
put verbose mode off
~CONFIG
SNOOP;STATUS
END
~STATUS
The result is:
BUSY;0
PAPER;0
RIBBON;0
PRINT HEAD;0
COUNT;000
GAP;0
HEAD HOT;0
CUT COUNT;000000000
PRINT DIST;000001529
PRCT COMPLETE;000
TOF SYNCED;1
SENSED DIST;00450
END
Read one RFID-EPC-code from current label
These are things mentioned in this command:
~CREATE - start creating a new "form" (or subroutine to execute later)
VERIFY - the name of the subroutine we are creating. Keep it simple,
less than 15 characters, no special signs (see docu PTX_PRM_PGL_P7_253642C
page 60 under "CREATE" and page 29 under "Form Name" for exact informations)
NOMOTION - don't move the label to the next one after executing this job
DF511 = This is a variable-name, there seem to be a lot of variables in the printer
which are called by their numbers: DF1, DF2, ... I don't know which one I am
allowed to use, DF511 seems to work
96 = the RFID-EPC on my labels are 96 Bits long
H = Hexnumbers, the code is 96 Bit long, but I would like to see it like this:
ABC1234...567
VERIFY - a command to send information to the commandline.
~EXECUTE;VERIFY;1 - execute the form 1 time
~CONFIG
SNOOP;STATUS
END
~CREATE;VERIFY;432;NOMOTION
RFRTAG;96;EPC
96;DF511;H
STOP
VERIFY;DF511;H;*STARTEPC=*;*=ENDEPC\n*
END
~EXECUTE;VERIFY;1
~NORMAL
The result is:
STARTEPC=E28068940000501EC931EC87=ENDEPC
Read two RFID-EPC-codes
Reads 2 Barcodes and gives back the EPC-codes. With this command the label get
sent (moved) through the printer.
These are things mentioned in this command:
~CREATE - start creating a new "form" (or subroutine to execute later)
VERIFY - the name of the subroutine we are creating. Keep it simple,
less than 15 characters, no special signs (see docu PTX_PRM_PGL_P7_253642C
page 60 under "CREATE" and page 29 under "Form Name" for exact informations)
NOMOTION - don't move the label to the next one after executing this job
DF511 = This is a variable-name, there seem to be a lot of variables in the printer
which are called by their numbers: DF1, DF2, ... I don't know which one I am
allowed to use, DF511 seems to work
96 = the RFID-EPC on my labels are 96 Bits long
H = Hexnumbers, the code is 96 Bit long, but I would like to see it like this:
ABC1234...567
VERIFY - a command to send information to the commandline.
~EXECUTE;VERIFY;1 - execute the form 1 time
~CONFIG
SNOOP;STATUS
END
~CREATE;VERIFY;432
RFRTAG;96;EPC
96;DF511;H
STOP
VERIFY;DF511;H;*STARTEPC=*;*=ENDEPC\n*
END
~EXECUTE;VERIFY;2
~NORMAL
The result is:
STARTEPC=E28068940000501EC931EC87=ENDEPC
STARTEPC=E28068940000401EC931EC86=ENDEPC
I have a bit of code that creates a salix webapp and runs it from an IDE popup menu by making use of util::Webserver. In order to allow for the command to be used multiple times, I try to shutdown any existing webserver at that address first but it doesn't seem to be working. No matter what it always comes up with an illegal argument error stating "shutdown" not possible.
void run_game(Tree t, loc s){
t = annotate(t);
PSGAME g = ps_implode(t);
Checker c = check_game(g);
Engine engine = compile(c);
loc host = |http://localhost:9050/|;
try { util::Webserver::shutdown(host);} catch: ;
util::Webserver::serve(host, load_app(engine)().callback, asDaemon = true);
println("Serving content at <host>");
}
What I expect to happen is that the first time this function it run, shutdown throws an error that is silenced because no webserver exists and then serve starts the webserver. If the user tries to run the function again then shutdown successfully runs, clearing the address bind and serve binds successfully to the address.
What actually happens the second time, is that shutdown still errors, the error is silenced and then serve complains that the address is already in use.
I'm looking for any solution that would allow me to start a salix app through the IDE's popup menu (previously registered) at the same address.
PS_contributions =
{
PS_style,
popup(
menu(
"PuzzleScript",
[
action("Run Game", run_game)
]
)
)
};
registerContributions(PS_NAME, PS_contributions);
Right; we ran into similar issues and decided to special case actions that run web apps. So we added this:
data Menu = interaction(str label, Content ((&T <: Tree) tree, loc selection) server)
See https://github.com/usethesource/rascal-eclipse/blob/bb70b0f6e8fa6f8c227e117f9d3567a0c2599a54/rascal-eclipse/src/org/rascalmpl/eclipse/library/util/IDE.rsc#L119
Content comes from the Content module which basically wraps any Response(Request) servlet.
So you can wrap your salix webApp in a Content and return it given a current selection and the current tree.
The IDE will take care to start and also shutdown the server. It does that every time an interaction with the same label is created or after 30 minutes of silence on the given HTTP port.
How do I make the script wait for the bridge to terminate before continuing when I have "bypass_media" set to true?
This snippet -
freeswitch.consoleLog("err","session before="..tostring(session:ready()).."\n")
session:execute("set","bypass_media=true")
session:execute("bridge","sofia/gateway/carrierb/12345678")
freeswitch.consoleLog("err","session after="..tostring(session:ready()).."\n")
from an audio perspective, it works perfectly with bridge_media set to either true or false, and a wireshark trace shows the audio either passing through (false) or end to end (true).
But with bypass set to true, the script continues without pausing, and the session is no longer ready (session:ready() == false).
The channel seems to go into a hibernate state, but I have housekeeping to do after the bridge is finished which I simply cannot do.
Same happens if i do the bridge in XML dialplan, immediately carries on causing my housekeeping to fire early.
FreeSWITCH (Version 1.6.20 git 43a9feb 2018-05-07 18:56:11Z 64bit)
Lua 5.2
EDIT 1 -
I can get "api_hangup_hook=lua housekeeping.lua" to work, but then I have to pass tons of variables and it fires up a new process/thread/whatever, which seems a little overkill unless that's the only way.
I have a workaround, but would still like an answer to the question if anyone has one (ie how to stop the bridge exiting immediately).
If I set this before the bridge :
session:execute("set","bypass_media=true")
session:execute("set","session_in_hangup_hook=true")
session:execute("set","api_hangup_hook=lua housekeeping.lua "..<vars>)
then "housekeeping.lua" fires when the bridge actually terminates (which is long after the script does).
In housekeeping.lua I can then do :
session:getVariable("billmsec")
and it seems to have the correct values in them, allowing me to do my housekeeping.
My problem with this is the uncertainty of playing with variables from a session that appears to have gone away from a script that fires at some point in the future.
Anyway, it'll have to do until I can find out how to keep control inside the original script.
EDIT: what I'm trying to do is essentially configure the station after
the softap is running a TCP server.
I get a panic error for wifi.sta being nil when I call wifi.sta.config(station_cfg) even after I configured it properly before.
When I do:
function connectHib()
wifi.setmode(wifi.STATIONAP)
[AP config here]
station_cfg={}
station_cfg.ssid = ""
station_cfg.pwd = ""
station_cfg.save = false
station_cfg.auto = false
wifi.sta.config(station_cfg)
end
It works fine, but when I call it, then start a server with srv=net.createServer(net.TCP) and then call the following function:
function validateSTA()
station_cfg={}
station_cfg.ssid = _G.wifi
station_cfg.pwd = _G.senha
station_cfg.save = false
station_cfg.auto = false
wifi.sta.config(station_cfg) -- this creates an error
wifi.sta.connect()
end
It gives me a PANIC error on the commented line. I'm just trying to reconfigure the STATION module only and then tell it to connect so I can validate the conection.
I'm using:
NodeMCU custom build by frightanic.com
branch: master
commit: 67027c0d05f7e8d1b97104e05a3715f6ebc8d07f
SSL: false
modules: adc,file,gpio,net,node,pwm,sjson,tmr,uart,wifi
build created on 2018-04-16 13:55
powered by Lua 5.1.4 on SDK 2.2.1(cfd48f3)
What bugs me is why it seems like it has not been "declared" before, but it works on the first function... I thought wifi. was global like _G. variables.
It also works if I call the functions separately on the ESPlorer command line on an ESP without my init.lua.
I also tried the debug firmware and the only odd thing I saw poping up was wifi_event_monitor_handle_event_cb that is called every 4 secconds or so.
Thanks guys, any help is apreciated as I'm stuck about a week now.
Like many other script languages, lua doesn't have declarations, only assignments.
You should perform checks what is wifi's value during the first and the second calls. It seems that at first you are using it as a table, and in the second function you try to use it as a string in the station_cfg.ssid = _G.wifi.
Or the reason is that global variables are not "like _G", they're stored in _G.
On an ESP8266, a LUA tmr.create() fails. Just a single line of code from the nodemcu docs. I've yet to get this working; stumped; have found nothing on the 'net here or forums. Posted in several other places with no replies. Odd
Basic node commands work. And, here's the thing that's getting me: some timer functions work - for instance tmr.alarm() does - but tmr.create() doesn't.
QUESTION 1: if the tmr module is loaded, isn't the entire module loaded, not just parts of it?
When I try this one line copied directly from the NodeMCU docs, it fails:
local mytimer = tmr.create()
with the usual message, I understand to mean an object is undefined:
stdin:1: attempt to call field 'create' (a nil value)
QUESTION 2: What am I missing or doing wrong?
Nodemcu's flasher successfully sent its default
INTERNAL://NODEMCU # 0x00000
NodeMCU 0.9.5 build 20150318
The board is an Adafruit Huzzah ESP8266, not a NodeMCU board. They both use the same ESP12, I think, so that shouldn't matter (or I hope it doesn't :-/)
NodeMCU 0.9.5 build 20150318
There's your culprit. That version is ancient. create() was added much later. Build a recent version from the master branch, https://nodemcu.readthedocs.io/en/master/en/build/ (note master in the URL), and flash that one.