I am using telerik report table for report generation
I have issue regarding data are not set on page side by side , It will kept some space and start data printing from new pages , accepted result is that in report data will be print side by side , there is not allow any kind of white space in between report
How can I achieve that in telerik report,
here by I attached screenshot of that issue
Please let me know , I am not able to find any way for set data in linear way without putting any space between pages
Thanks !!!!
In the table property, make "KeepTogether : False" in the Behavior section.
Related
My data contains around 10000 records.
I have published my workbook in the browser. I am able to see the summary and full data in Tableau (2022.1.1) version.
But I am unable to see the content in Full data in View data ( version - 2021.4.8).
Thanks in Advance.
Firstly, "View Data" is just a preview option for your data and it will only show those fields which belong to the viz used in your dashboard
I have a Report and in my Detail i put a SubReport with the following properties:
When the SubReport has more than one page, the next page gets blank, like in the images following:
It looks like, this next blank page, is related to the SubReport data, but it doesn't show anything, and after this blank space, the report keep normaly showing the rest of the data.
Anyone knows what can i do to show the data of the subReport when he generates more tha one page?
Try to set TfrxSubreport.PrintOnParent to True
You don't use Fast Report's TfrxSubreport on the Properties screenshot. TppSubReport is not FR's class
I'm very new to scripting and really need some help getting started.
Basically I'm trying to develop a simple script to show a warning message when a certain value in a cell has been selected from a drop down list.
When the option 'Behind' has been selected I just want a simple popup window or something to say 'Review is needed'.
I've explored 'toast' but I'm not sure how I'd get the script to run based on the value.
Any help would be much appreciated, I'm going bald :(
Emma
You can also achieve this kind of behavior without writing your own script. See Data validation.
Select the cells for which you want this to apply
Click on Data -> Data Validation in the menu
Set your criteria for allowed values
On invalid data, select either Show Warning or Reject Input (the latter will reject the input and show a toast)
Put a checkbox in Show validation help text to add a custom warning text
I have created a report using FastReport Designer (Delphi 2010). I have one TfrxIBXQuery (Query1) connected with main database -Base1(frxIBXComponents.DefaultDatabase:=Base1). It works fine, I can get data using Query1+MasterData band.
The problem arises when I'm trying to get data from another database in the same report.
In Designer I drop new frxIBXDatabase (Base2), set the necessary properties. Add new TfrxIBXQuery (Query2) and connect it with Base2.
But I can't get any data from Query2 because it does not see Base2.
How do I solve this problem?
When you look at the properties tab from your query component, can you see any FieldAliases?
If not, you should check the SQL, FastReport can be really picky when it comes to parameters.
Try changing parameter names and see if that works.
If you want to use two or more databases inside report - you should use two TfrxIBXDatabase inside report (on the Data tab)
Clear frxIBXComponents.DefaultDatabase property
I have a telerik MVC grid. After making some changes to the underlying code, the grid no longer shows the results returned from the server. I can see the correctly formatted JSON return from the server (using functionality from Web Developer Toolbar), but the grid never actually shows the data. However, it also doesn't generate an error. The loading icon just keeps spinning.
Does anyone have a suggestion on how to localize the problem? Thanks.
EDIT
Well, I managed to get a step further. Apparently something goes wrong in the "bindData"-function located in telerik.grid.js. More specifically in line 462:
460. var evaluate = column.display;
461. if (evaluate)
462. html.cat(evaluate(data[rowIndex]));
When trying to render the last column in the first row, evaluate is set to anonymous and somehow, this results in an "invisible" exception. The markup of this column is:
columns.Bound(c => c.DocumentId)
.ClientTemplate("<a href=\"" + Url.Content("/") +
"/document/<#= DocumentId #>\" target=\"_blank\"><#= Naam #></a>")
.Filterable(false)
.Title("Naam");
I don't understand why this would be a problem, as I use similar templates elsewhere without any problem.
EDIT
Ok, I got it. Apparently some exceptions will not be shown in the Firefox/Firebug console. However, Visual Studio together with IE do not have this problem. I finally discovered that indeed the field "Naam" was missing in the IEnumerable.
So something to take away here is never to trust the results from just one browser ;-)
I had a similar behaviour recently when I had changed the type that the grid was expecting.
Make sure that your ajax call is returning the correct IEnumerable that is specified in the grid markup.
You need to post code for the GridAction and markup if you want a more accurate answer.