Starting thingsboard service on windows Error 1067 - thingsboard

I am getting the below error when I run net start thingsboard
A system error has occurred.
System error 1067 has occurred.
The process terminated unexpectedly.

Problem was with windows service java wrapper
I was able to run thingsboard from command line with out using service wrapper using below command :
SET BASE=C:\thingsboard
SET LOADER_PATH=%BASE%\conf,%BASE%\extensions
SET SQL_DATA_FOLDER=%BASE%\data\sql
SET jarfile=%BASE%\lib\thingsboard.jar
SET installDir=%BASE%\data
java -jar thingsboard.jar

I had same Problem that I solved by giving correct path of java in
Control Panel\All Control Panel Items\System\Advanced system settings\Advanced\Environmental Variables\System variables
In system variable select Path and click on Edit and give your java version path
for example mine is:
C:\Program Files\Java\jre1.8.0_172\bin
if this is not working check whether multiple java versions are available or not.
there should not be multiple java path in Environment Variables if its there delete others and let only correct path

Related

Neo4J windows installation

Downloaded Neo4j community version, the file named "neo4j-desktop-offline-1.1.13-setup.exe". Running the binary successfully installed. Launching the application takes me to configuration of database location "Please choose path where you want to store application data" and regardless of what path i choose, clicking "Confirm" does not do anything at all and it remains on the same screen.
Am using Windows 10.
I also got the same problem. I fixed it by adding a new PATH in environmental variables,
Advanced System Settings > Environment Variable > system variable > path > new: C:\Windows\System32\wbem
After setting, reopen the Neo4j application and it will allow you a select the path where you want to save application data.
REASON
In the developer console, you will see the following error
Uncaught (in promise) Error: Command failed: wmic logicaldisk get
size,freespace,caption 'wmic' is not recognized as an internal or
external command, operable program or batch file.
The actual WMIC binary is located at C:\Windows\System32\wbem\WMIC.exe you need to set the path if it is not yet defined.
try opening http://127.0.0.1:7477 or http://localhost:7474 in your browser
I had the same problem using Windows 7, and after trying the solutions others have suggested around fixing the Path environment variable to no avail, I found upgrading PowerShell solved the problem. To do this, I upgraded my Windows Management Framework (to 5.1 at the time of this writing) by following the appropriate link for my version of Windows from here:
https://learn.microsoft.com/en-us/powershell/scripting/windows-powershell/install/installing-windows-powershell
For Windows 7, I retrieved Win7AndW2K8R2-KB3191566-x64.zip from the Download link found here: https://www.microsoft.com/en-us/download/details.aspx?id=54616.
I unzipped and installed it, and after a reboot it worked (for Neo4j Desktop 1.4.15). Upgrades to WMF for other versions of Windows are on the same page.

How to install WebLogic AdminServer and NodeManager as windows service?

I am trying to install Weblogic adminserver as windows service but getting "Input too long" error while executing the install script.
I have struggled a lot in this issue and finally got the way to register AdminServer and Nodemanager as windows service for Weblogic. Below are the steps and issues faced with the progress:
To register weblogic AdminServer as windows server first need to create a script which will contain values like oracle home, java home etc. Below is the script I have used to install the service:
`
echo off
SETLOCAL
set MW_HOME=C:\Oracle\Middleware\Oracle_Home
set DOMAIN_NAME=osb_domain
set USERDOMAIN_HOME=C:\Oracle\Middleware\Oracle_Home\user_projects\domains\osb_domain
set SERVER_NAME=AdminServer
set WL_HOME=C:\Oracle\Middleware\Oracle_Home\wlserver
set PRODUCTION_MODE=true
set JAVA_OPTIONS=-Dweblogic.Stdout="%USERDOMAIN_HOME%\stdout.txt" -Dweblogic.Stderr="%USERDOMAIN_HOME%\stderr.txt"
set WLS_USER=weblogic
set WLS_PW=Password123
set MEM_ARGS=-Xms1024m -Xmx1024m
call "C:\Oracle\Middleware\Oracle_Home\user_projects\domains\osb_domain\bin\setDomainEnv.cmd"
call "C:\Oracle\Middleware\Oracle_Home\wlserver\server\bin\installSvc.cmd"
ENDLOCAL
`
By running this script I was not even able to install the windows service as it was throwing " Input is too long" error and the reason is windows char limitations. You might get confused by classpath and will try to resolve classpath but
the issue is with JAVA_OPTIONS values which is set by SetDomainEnv.txt is creating this issue.
I have modified the script like below and shorten the JAVA_OPTIONS values by calling SetDomainEnv.txt command just before setting JAVA_OPTIONS in the script.
This has overridden the lengthy value of JAVA_OPTIONS. Now I have succesfully installed the AdminServer as windows service.
`
echo off
SETLOCAL
set MW_HOME=C:\Oracle\Middleware\Oracle_Home
set DOMAIN_NAME=osb_domain
set USERDOMAIN_HOME=C:\Oracle\Middleware\Oracle_Home\user_projects\domains\osb_domain
set SERVER_NAME=AdminServer
set WL_HOME=C:\Oracle\Middleware\Oracle_Home\wlserver
set PRODUCTION_MODE=true
call "C:\Oracle\Middleware\Oracle_Home\user_projects\domains\osb_domain\bin\setDomainEnv.cmd"
set JAVA_OPTIONS=-Dweblogic.Stdout="%USERDOMAIN_HOME%\stdout.txt" -Dweblogic.Stderr="%USERDOMAIN_HOME%\stderr.txt"
set WLS_USER=weblogic
set WLS_PW=Password123
set MEM_ARGS=-Xms1024m -Xmx1024m
call "C:\Oracle\Middleware\Oracle_Home\wlserver\server\bin\installSvc.cmd"
ENDLOCAL `
Even the service is successfully installed, when I was starting it the service is stopped immediately and wasn't printing any logs as it was not connecting to AdminServer.
After a bit analysis I found that JAVA_OPTIONS values which I have overridden in my script is very much needed to invoke AdminServer.
I have run SetDomainEnv.txt in cmd prompt and copied thre JAVA_OPTIONS values.
As the service is already installed, I just copied the correct JAVA_OPTIONS values CMDLINE param in the windows service registry manually.
Server subsystem failed. Reason: A MultiException has 6 exceptions.
Server installed as Windows NT service with incorrect password for user weblogic. The password may have been changed since the server was installed as a Windows NT Service. Contact the Windows NT system administrator.
Note: No extra spaces or character is inserted in CMDLINE param.
Now everything is in place which is actually required to start the admin server. But when I start the service it is throwing some authentication error along with others in the adminserver.log file.
after a lot of analysis I found that is is not authentoication issue, the problem was with boot.properties file. boot. properties file was not read properly.
This answer is continuation of below one:
after a lot of analysis I found that is is not authentoication issue, the problem was with boot.properties file. boot. properties file was not read properly.
Now I would give some background- If the fusion middleware is installed as development mode the boot.properties files is created automatically inside Oracle_HOME\user_projects\domains\domainname\servers\AdminServer\security and if you look at this prop file you will find the password and username in encrypted mode.
If the fusion Middleware is installed as production Mode then everytime it will ask for password and username. to avoid this perform below steps:
manually create file under Oracle_HOME\user_projects\domains\domainname\servers\AdminServer\security\boot.properties like mention below:
username=weblogic
password=Password
Note: No spaces should be added and take care of file extension.
Now start weblogic from domain\bin\startWeblogic.cmd. This will encrypt you boot.properties file. check boot.proprties file if encrypted you are good to go.
Finally start the windows service whic is installed following above process. It should work fine.
=======================
About Node manager use installNodeMgrSvc from domain\bin. Again if you get input is too long error, you must shorten JAVA_OPTIONS and then carefully edit CMDLINE param in the windows registry.

Windows x64 RabbitMQ install error with Erlang environment var (ERLANG_HOME)

I'm ask/answering this question because it hung me up & it's likely someone else will have the same problem.
Install of RabbitMQ x64 v2.8.6 on Windows Server 2008 x64.
After Erlang install using default install location to C:\Program Files\erl5.9.2, I'm attempting to start the server via running the rabbitmq-service.bat. Fail:
Please either set ERLANG_HOME to point to your Erlang installation
or place the RabbitMQ server distribution in the Erlang lib folder.
Problem is the .bat file does not have the correct subpath. with 5.9.2 (R15B02) version of erlang. My ERLANG_HOME directory is set correctly, but the script does not use it correctly for this version of Erlang, which, it appears to this Erlang noob to have a new subdirectory called "erts-5.9.2" which is causing the problems. Maybe someone intimate with these scripts can describe how to make this work correctly without the hack workaround I'm about to describe?
1- Set environment variable:
Variable name : ERLANG_HOME
Variable value: C:\Program Files (x86)\erl6.4
note: don't include bin on above step.
2- Add %ERLANG_HOME%\bin to the PATH environmental variable:
Variable name : PATH
Variable value: %ERLANG_HOME%\bin
This works well.
There are several RabbitMQ control .bat files on windows. Every one you use needs to get changed to reflect the Erlang path correctly. In this example, I'm editing the rabbitmq-server.bat because it's one of the easier ones... any of the .bat files you want to run will need this hack to get them to work, with the rabbitmq_service.bat file being the most involved to adjust.
editing that rabbitmq_server.bat file, you can see on about line 48 or so there's a check to see if the erl.exe is found, but the path isn't correct:
if not exist "!ERLANG_HOME!\bin\erl.exe" (
that path does not match the file structure for the 5.9.2 version of Erlang. I fixed this by simply removing this path check from about line 48 to 58, then, where the .bat actually makes a call to the erl.exe on about line 129 which reads:
"!ERLANG_HOME!\bin\erl.exe"
I simply hardcoded the path to my erl.exe:
"C:\Program Files\erl5.9.2\erts-5.9.2\bin\erl.exe"
With the pathing correct, the rabbitmq .bat files will run.
I had the similar issue, modifying ERLANG_HOME in .bat files did not work. Then I tried echo %ERLANG_HOME% in command prompt, that did not print the environment variable value(I could see that ERLANG_HOME environment variable has been created under advance system settings), that lead me to believe that I need to restart server for 64 bit installation of Erlang. After rebooting server, It worked like a charm. I hope this helps someone.
Just to share an up-to-date answer as of 2019: On Windows Server 2019, after setting up the environment variable, a restart is required to solve the problem.
I got into same kind of problem.
I solved it by doing three changes as given below.
Update Path variable "ERLANG_HOME" : "C:\Program Files\erl8.0" in Environment Variables.
Upadte "Path" variable "Path" : ";%ERLANG_HOME%\bin;"
Give urself FULL CONTROL permissions over "Program Files" in C drive.
It worked for me in this way.
This problem still occurs in Erlang 18.3 (erl7.3) and RabbitMQ 3.6.9 on Windows when upgrading from any older version of RabbitMQ to version 3.6.9. The solution as already stated here is to manually set ERLANG_HOME with 'setx -m ERLANG_HOME "C:\Program Files\erl7.3"' before starting the service.
What happens is that the RabbitMQ 3.6.9 installer removes the environment variable ERLANG_HOME from the system while removing the older version of RabbitMQ. Then, when it proceeds to the installation step, it does not put back the ERLANG_HOME variable. Then, the batch files that start up RabbitMQ cannot find Erlang. They try to find Erlang's home directory using "where.exe" but it always fails after an upgrade.
RabbitMQ's installer also does not kill all of the Erlang background processes, causing many of its files to be undeletable due to the Windows "file in use" problem. This leaves behind "files in use" in %APPDATA%\RabbitMQ and "C:\Program Files\RabbitMQ." These processes are "erl.exe," "erlsrv.exe," and "epmd.exe." The RabbitMQ installer should taskkill these processes after shutting down the RabbitMQ Windows service.
RabbitMQ is rather clunky on Windows.
Download Erlang or OTP - Only one Version of OTP should be installed
Download RabbitMQ installer
Install both exe file as Administrator
Set class path for Erlang. (Setting classpath is a bit troublesome, so follow these steps)
Set a new path with name ERLANG_HOME and value C:\Program Files\erl-23.1 (do not copy bin folder here)
Edit System "path" and add %ERLANG_HOME%\bin
Go to Start - Open rabbitmq command promt and run
rabbitmq-plugins enable rabbitmq_management
Navigate to localhost:15672
Use guest/guest to login
Interesting that this worked for you. There is record of a two bugs in Erl5.9.2 that cause an incomplete installation where %ERLANG_HOME%\bin is not installed.
Either of
* Installed 64bit erlang on 32bit machine
* "The program can't start because MSVCR100.dll is missing from your computer."
https://groups.google.com/d/topic/erlang-programming/wGtFLzapiQ0/discussion
Try 5.9.1 or any other version. They also mention making the future versions of the installer alert you if it fails.
I just had the same problem mentioned here. I installed otp_win64_R15B02 on a Windows 7 machine and everything worked perfectly, but I used the same installer on a Windows 2008 server and the bin directory was not created. I then uninstalled otp_win64_R15B02 and downloaded the otp_win64_R15B02_with_MSVCR100_installer_fix and the bin directory was created.
I suspect the reason it worked on my Windows 7 system is that I have Visual Studio installed and the required libraries were already available which allowed the otp_win64_R15B02 installer to work correctly.
Oh, and if you're installing Erlang to run RabbitMQ the RabbitMQ install will succeed with the broken installer but installing otp_win64_R15B02_with_MSVCR100_installer_fix after RabbitMQ will not work, just un-install and re-install RabbitMQ to resolve this.
Just give C:\Program Files\erl10.6\ not C:\Program Files\erl10.6\bin\erl.exe in the environment variable. If you open the server.bat file I came to know the issueenter image description here
I think this is encoding issue on windows.I see a correct value but I write echo %ERLANG_HOME% on console the value come with question mark. These steps fix it.
1.go environment variable window
2.edit ERLANG_HOME item
3.copy the value, open notepad and paste there
4.copy again on notepad and paste to edit window
5.apply and exit window
6.close command line tools and reopen
7.run rabbitmq bat file.
I solved it in a quick and dirty way,without naming path variables
I've opened the bat file and replaced every occurrence of
!ERLANG_HOME!\bin\erl.exe
with hard coded path for example might be diffrent path for you because of diffrent version
C:\Program Files\erl10.3\erts-10.3\bin\erl.exe
and replaced
%RABBITMQ_HOME%\escript\rabbitmq-plugins
with
C:\Program Files\RabbitMQ Server\rabbitmq_server-3.7.14\escript\rabbitmq-plugins
Even I was this problem. The issue was the environment variable ERLANG_HOME=c:\Program Files\erl9.0 which was never existed.
I cross checked the path. The correct path was c:\Program Files\erl9.3.
After correcting the
ERLANG_HOME=c:\Program Files\erl9.3
the problem solved. So, definitely it is a path issue.
In my case, it should be installed erlang using admin role running
If above solutions doesn't work for you then you can try following
Find another compatible version of erlang for your rabbit mq e.g. for rabbit 3.7.x erlang version 20.3.x to 22.0.x all are compatible .
Right click newly downloaded erlang version and from properties select the option to unblock the file .
Run the erlang with admin persssion .
Re run rabbit mq exe

Error in running RMIC via Ant using wsejbdeploy taskdef

I get the following exception when trying to generate RMIC using Ant task.
[wsejbdeploy] Error generating RMI code: RMIC command failed on project: .... with message:
[wsejbdeploy] error: The IBM RMIC version 0x1500 does not match the IBM runtime version 0x1600.
Please let me know how to fix this.
I am trying this using the WebSphere 6.1 server that comes bundled with RAD7.5.
This works fine when we use IDE to generate the EAR, and fails only when we use our custom Ant build file.
The error means that JAVA_HOME in your shell used to invoke Ant is different from the Java that was included with the embedded WebSphere Application Server. Try using the WAS_HOME/bin/ws_ant script, or set JAVA_HOME to WAS_HOME/java/.
The error
Cannot run RMIC because it is not installed. Expected location of RMIC is the following:
will some times confuse. enable the "Capture RMIC verbose output to the workspace .log file.
and see what the exact error your getting. This option will be available in properties > EJBDeployment.
In My case it throwing error due to huge number of jars in class path.It got resolved after shortening the class path jar location.

MDS-CS in blackberry

When I run my simulator I obtain an error that java 1.6 cannot found for launching MDS-CS
Can any one help me ? What should I add to run MDS-CS?
open command prompt and type java. If you get "java not recognized as an internal or external command" , you havent set the path. MDS-CS needs JDK path to be set. So as Farid farhat told you,set the path in environment variables to point to bin folder in JDK.

Resources