Why the email I send via the INSTRUCTOR > EMAILS is truncated? - openedx

1) Given my email, produced via a mailchimp online editor.
2) I go to my openEdX, log in as administrator of the MOOC. Then got to My MOOC > INSTRUCTOR > EMAILS, in order to send my email. First a test to myself, later to my 2000 mooc students.
3) The email I receive in my inbox is CUT HALF WAY. The bottom part is all missing.
QUESTION : What is going on there ? How to fix this ?

Look into your code for the first paragraph which disapeared. It's likely the buggy part.
For this case, I can see the first disappeared sentence is :
đź’ˇ Astuce : Pensez Ă  inviter NudiMooc Ă  suivre votre BLOG
My eyes are catched up by the strange đź’ˇ sign, which is a rare unicode character.
Delete this exotic đź’ˇ sign from your email / html5 code, and it will work again. I tested it by sending to myself. Horray ! The corrected code without the lightbulb was complete !! :D
OpenEdX processing may crash on this string. But because there are some witty security, the previous, valid text is kept.

Related

Quickfixj- Custom FIX msg - 35=F not working for Multileg

I am using quickfixJ 2.3
To parse the FIX message , we have used
MessageUtils.parse(msgFactory,dd,inPutFixMsg, false)
I am able to place the list order ,multileg - 35= AB, AC order.
Now when I want to cancel the multileg order created by AB,
I just replaced 35=F, added 41 tag.
Now I am getting error while parsing in Message.parse : tag 600 appears more than once.
I am interested to know ,the other cancel( new order cancel, future cancel) working fine. Even I have mentioned the dd, then still why m I getting the error?
Or is there any other approach ?
You can't just change the message type (tag 35) and assume all the other tags are going to be compatible!
AB and F messages have different tags in their body. They are totally different messages!
The amount of stuff about FIX that you need to know exceeds what is appropriate for a StackOverflow answer. You really need to read some docs about how FIX messages are structured and decoded.

Sending IFS File to Outq Prints Line of "#" Symbols

I am attempting to send a file from IFS to an outq on our AS/400 system. Whenever I do, I get exactly what I send, as well as a line of "#" symbols of varying lengths appended to the end.
Here's the command I'm using:
qsh cmd('cat -c /path/test.txt | Rfile -wbQ -c "ovrprtf file(qprint)
outq(*LIBL/ABCD) devtype(*USERASCII) rplunprt(*no) splfname(test) hold(*no)"
qprint')
The contents of test.txt is just Hello World!
The output I get when I send the command is
Hello World!####################################################################
I have not found any posts online about a similar problem, and have tried changing values and looking for additional switches to get it to work. Nothing I'm doing seems to fix the issue.
Is there a command or switch that I am missing, or is something I have in there already causing this?
EDIT:
I found this documentation which is the first time I've seen this issue mentioned, but it's not very helpful:
“Messages for a Take Action command might consist of a long string of "at" symbols (#) in a pop-up message. (The Reflex automation Take Action command, which is configured in situations, does not have this problem.) A resolution for this problem is under construction. This problem might be resolved by the time of the product release. If you see this problem, contact IBM Software Support.”
The only differences are: 1) this is not a pop-up message, it's printed. 2) I don't believe we use Tivoli Monitoring, although I could be wrong.
Assuming we do use Tivoli Monitoring, what would the solution be? There's no additional documentation past that, and I am not a system administrator, so I can't really make the call to IBM Software Support myself. And assuming we DON'T use it, what else could cause this issue?
I get different results, yet similar. I created a test.txt with Windows Explorer, put in Hello, world!, saved it and tried the script. I got gibberish for the 'Hello, world!' and then the line of # symbols.
My system is 7.3 TR5, CCSID 37 (US English) and my IFS file is CCSID 1252 (Windows English). Results did not change if I used a stream file of CCSID 819 (US ASCII).
I didn't have any luck modifying Rfile switches.
I found that removing devtype(*userascii) produced printed output in plain English without the # symbols. Do you really need *USERASCII? I would think that would be more for a pre-formatted 'print-ready' file like Postscript or the like.
EDIT: some more things to try
I don't understand why *USERASCII is adding those # symbols; it looks like a translation issue.
I tried this and still got the extra ###... You might have to play with the TOCCSID() parameter. Although a failure, it did give me an idea: what if those # symbols are EBCDIC spaces being sent as-is to the *USERASCII print stream? All we'd need is a way to send only the number of bytes in the stream file, without any padding.
CRTPF FILE(QTEMP/PRTSTMF) RCDLEN(132)
CPY OBJ('/path/test.txt') TOOBJ('/qsys.lib/qtemp.lib/prtstmf.file/prtstmf.mbr') replace(*yes)
ovrprtf file(qprint) outq(*LIBL/prt3812) devtype(*USERASCII) rplunprt(*no) splfname(test) hold(*no)
cpyf prtstmf qprint
The data in QTEMP/PRTSTMF is in ASCII; DSPPFM shows that much. It also shows a bunch of spaces: after all, it is a fixed length file. My next step was to write an RPG program to read the stream file and print it, but Scott Klement already did that: http://www.scottklement.com/PrtStmf.zip
This works on my system:
ovrprtf file(qsysprt) outq(*LIBL/abcd) devtype(*USERASCII) rplunprt(*no) splfname(test) hold(*no)
prtstmf stmf('/path/test.txt') outq(abcd)

Does the Zebra QLn220 printer have a "Flush" Command?

The ZebraQLn220 has many settings that can be programmatically updated via commands sent it, such as:
! U1 setvar "media.sense_mode" "bar"
However, sometimes it takes several attempts before that change is "seen"/accepted/applied by the printer. For instance, I have sent the
! U1 setvar "power.dtr_power_off" "on"
command several times before this one:
! U1 getvar "power.dtr_power_off"
...will finally respond back with "on" (giving me "off" instead the first several times).
So: Is there a command that can be sent to the QLn220 that tells it to "flush" or "write all changes" or "save changes" or "I really mean it this time" or some such?
UPDATE
I don't know what firmware is new enough, but this is what the printer tells me about itself as far as "appl" settings go:
appl.date : 2/19/2014
appl.name : V68.19.7Z
appl.version : 6819
appl.bootblock : 2.5.9
appl.link_os_version : 2.0
If you are using later firmware you can use JSON to format the commands. In this method the commands will respond immediately with the configured values.
{}{"media.sense_mode":"bar"}
would respond with:
{"media.sense_mode":"bar"}
You can also put multiple requests in one:
{}{"media.sense_mode":"bar",
"power.dtr_power_off":"on"
}
The following knowlege base article has more info - https://km.zebra.com/kb/index?page=content&id=SO8638&actp=RSS

Standard print button is inoperative in custom Report

My customer has reported a problem that standard ''print'' button in Z-report which a developer wrote before is not working.
How can I enable the button?
MODULE user_command_0100 INPUT.
DATA: GS_STATUS TYPE SLIS_STATUS,
XS_STATUS LIKE GS_STATUS.
CASE sy-ucomm.
WHEN 'BACK' OR '%EX' OR 'RW'.
LEAVE TO SCREEN 0.
WHEN '&RNT'.
ENDCASE.
ENDMODULE.
Then button needs a usercommand assigned, which is then processed in pai. usually with a general form called get_ucomm (many developers call it similar). You also can issue /h in transaction field and then press the print-button. /h will trigger the debugger and You can inspect the report step by step.
That's all I can say without seeing the code. Hope this will help.
Which user command do you define in your GUI status?
If you have a standard list (what I expect when you write about a z-report), then you should define the command PRI to print the list:
If you define a screen (using the screen painter) or an ALV-Grid... then this solution will not help you.
If you don't know, what a GUI status is: Scan your source code for the command
SET PF-STATUS 'XXXX'.
Then double click on 'XXXX' and you should be directed to the status definition. There may by multiple status (and status with generic names).
I've seen your code and for the &RNT option there's no code to execute, so if the user wants to print the button will do nothing.
MODULE user_command_0100 INPUT.
DATA: GS_STATUS TYPE SLIS_STATUS,
XS_STATUS LIKE GS_STATUS.
CASE sy-ucomm.
WHEN 'BACK' OR '%EX' OR 'RW'.
LEAVE TO SCREEN 0.
WHEN '&RNT'.
" There's no code
ENDCASE.
ENDMODULE.
I've used the 'STANDARD' GUI Status from the function group 'KKBL' and '&RNT' is the code of the print button and that's why I think that is the print button you are refering in your program.
Can you post the GUI Status you are using please?

Tag appears more than once while using Quickfix market data incremental refresh

I have implemented the fix client that request for market data. I have successfully logged on to the server but when the server sends us a MarketDataIncrementalRefresh message my application rejects with the message "Tag appears more than once" tag for which it is indicating is 55. Can you please help me in resolving it?
The message it rejects is:
8=FIX.4.2 9=196 35=X 34=14 49=Xenfin 56=newchange.api -price 52=20140528-08:54:32.144 262=156 268=2 279=1 269=0 278=B 55=EUR/USD 270=1.36201 271=1000000.00 279=1 269=1 278=A 55=EUR/USD 270=1.36205 271=1000000.00 10=133
and in my config file I have used no data dictionary and set UseDataDictionary=N
This usually means you have a configuration or DataDictionary problem, or both.
Configuration problem: Your config should have UseDataDictionary=Y, and DataDictionary=path/to/xml (or AppDataDictionary= and TransportDataDictionary= if you're on FIX5).
DataDictionary problem: Your counterparty has probably added custom fields to the message, and your DD hasn't been properly updated to reflect them. When parsing repeating groups, when the QF/n parser finds a field that doesn't belong (per DD) to the group, it assumes the group has ended. Any fields after that are considered to be outside the group.
You need to edit your DD file to reflect any changes that your counterparty has made to the standard message set. This will probably include adding custom fields, and may include rearranging field orderings or adding fields to groups that they don't normally belong in. See this page for more info about editing your DD:
http://quickfixn.org/tutorial/custom-fields-groups-and-messages
That's because you have a repeating group, once for bid, once for offer
8=FIX.4.2
9=196
35=X
34=14
49=Xenfin
56=newchange.api -price
52=20140528-08:54:32.144
262=156
268=2
279=1 269=0 278=B 55=EUR/USD 270=1.36201 271=1000000.00
279=1 269=1 278=A 55=EUR/USD 270=1.36205 271=1000000.00
10=133
and you're not handling it properly.